Sign in →

Test Code APTT-ANTICOAGULANT APTT-ANTICOAGULANT

Department

Coagulation

Specimen Type

Plasma

Method

Photometric Clot Detection

Container

Sodium citrate 3.2% (light blue-top)

Special Requirements

1.8 mL blue top tube available. Blue-top tube must be filled to the draw line. If testing is not to be performed within 4 hours, separate the plasma from the cells, and centrifuge the plasma a second time. Decant plasma and freeze @ -20 degress C). Send frozen. Results may be affected by freezing. Specimen must be taken to laboratory immediately.

Standard Volume

2.7ml

Minimum Volume

1.8ml

Pediatric Volume

N/A

Ship Temperature

See Stability

Stability Refrigerated

4 Hours

Stability Room Temp

4 Hours

Stability Frozen

7 Days

Spin down and separate plasma. Freeze plasma at -70° C.

CPT Code

85730

Days Test Set Up

Monday through Sunday

Group Components

APTT ANTICOAGULANT